- Operating Room Equipments
- Diagnostic Equipments
- Infant Equipments
- Sterilizer
- X-ray System
- Hospital Funiture
- Laboratory Equipments
- Clinical Analysis Equipments
- Dental Equipments
- Medical Consumables
Latest news
Contact us
- ADD: No.226, Anjia Industrial zone, Baoan District, Shenzhen China
- TEL: 86-13127871605
- FAX: 86-13127871605
- E-mail: sales@ankmed.com



ABN-100 Infant radiant warmer
Product introduction
Function Features:
Microprocessor based servo controlled temperature system
The microprocessor-controlled unit allows for three modes: pre-warm, manual and automatic
APGAR timer to record therapy time
Audible and visual Alarm functions :
Power failure, temperature deviation, temperature sensor failure, skin temperature failure, over temperature
LED observation light adjustable,brightness adjustable
Heater head can be adjusted ±90°horizontally
Convenient X-ray cassette board under infant bed
Tilt angle of infant bed is adjustable
Four Transparent protector folded with 2 infusion seals
With RS-232 connector,2 trays and 2 drawers
Skin temp T1,T2; Temp value and trend on 8″LCD Touch screen
APGAR timer and other parameters display on 8″LCD screen
ABL -60D Phototherapy unit
Technical data
Power supply AC110/220V 60/50Hz
Power input 1000VA
Environment temperature 18℃~30℃
Operating Environment relative humidity 30%~75%
conditions Atmospheric Pressure 700~1060hpa
Environment air velocity of flow <0.3m/s
Skin Temperature control range 32℃~38℃
Skin temperature control accuracy ≤0.5℃
Skin temperature sensor accuracy ±0.3℃
Mattress temperature uniformity <2℃
Infant Bed tilt angle ±10°
LED observation light function 3W
Warm-up time(from 25℃) <30min
Heater head horizontal ±90°
Distance from heater to mattress 80cm
Mattress size 67cmX54cm
APGAR Timer range 0~99h59min,singal per min at first 1h
Heating power 0-100%in5%step
Phototherapy Irradiance 20-70μw/c㎡/nm
Transport and storage
Package
Each unit is packed one plywood case
Size:118*90*87cm
N.W.:75Kg G.W.:100Kg
Transport and storage
Environment temperature -40℃~+55℃
Environment relative humidity ≤95%
Atmospheric Pressure 500~1060hpa
Standard configuration
Main body (including the Radiant source, Control
system,Infant bed, Bracket), X-ray cassette ,
Observe light ,I.V.pole, Skin temperature sensor,
Tray, Mattress, Transparent protector, Castors ,
Drawers
Reusable temperature sensor - 40 pcs. (20 skin and 20 peripheral)
Reusable AMBU bag for child – 2 pcs
Reusable AMBU bag for adult – 2 pcs
Reusable laryngoscope 1 pcs
Power supply AC110/220V 60/50Hz
Power input 1000VA
Environment temperature 18℃~30℃
Operating Environment relative humidity 30%~75%
conditions Atmospheric Pressure 700~1060hpa
Environment air velocity of flow <0.3m/s
Skin Temperature control range 32℃~38℃
Skin temperature control accuracy ≤0.5℃
Skin temperature sensor accuracy ±0.3℃
Mattress temperature uniformity <2℃
Infant Bed tilt angle ±10°
LED observation light function 3W
Warm-up time(from 25℃) <30min
Heater head horizontal ±90°
Distance from heater to mattress 80cm
Mattress size 67cmX54cm
APGAR Timer range 0~99h59min,singal per min at first 1h
Heating power 0-100%in5%step
Phototherapy Irradiance 20-70μw/c㎡/nm
Transport and storage
Package
Each unit is packed one plywood case
Size:118*90*87cm
N.W.:75Kg G.W.:100Kg
Transport and storage
Environment temperature -40℃~+55℃
Environment relative humidity ≤95%
Atmospheric Pressure 500~1060hpa
Standard configuration
Main body (including the Radiant source, Control
system,Infant bed, Bracket), X-ray cassette ,
Observe light ,I.V.pole, Skin temperature sensor,
Tray, Mattress, Transparent protector, Castors ,
Drawers
Reusable temperature sensor - 40 pcs. (20 skin and 20 peripheral)
Reusable AMBU bag for child – 2 pcs
Reusable AMBU bag for adult – 2 pcs
Reusable laryngoscope 1 pcs